xevi/user guides
Johan Berglund b80f9247a2 Added compile option to include a MPR121 board adress scanning function for troubleshooting (MENU button at startup). Changed the destination setup for bite and lever to be less confusing and more powerful (custom CCs now possible). The VIB CTL item in the VIBRATO menu is now removed, and in SETUP CTL menu you will find BITE CTL, BITE CC, LEVER CTL and LEVER CC.
BITE CTL and LEVER CTL can both be set to any of these destinations:
	OFF - no destination active for this controller
	VIB - vibrato
	GLD - glide/portamento (defined by GLIDE MOD and GLIDE LMT settings)
	CC  - custom CC output (defined in GLIDE CC and LEVER CC settings)

Settings in GLIDE CC and LEVER CC are only used when corresponding control is set to CC in its CTL setting as described above.
2020-09-04 11:32:40 +02:00
..
notes 1.5b4.txt Added compile option to include a MPR121 board adress scanning function for troubleshooting (MENU button at startup). Changed the destination setup for bite and lever to be less confusing and more powerful (custom CCs now possible). The VIB CTL item in the VIBRATO menu is now removed, and in SETUP CTL menu you will find BITE CTL, BITE CC, LEVER CTL and LEVER CC. 2020-09-04 11:32:40 +02:00
NuEVI user guide 146.doc New version documentation. 2020-04-27 11:21:36 +02:00
NuEVI user guide 146.pdf New version documentation. 2020-04-27 11:21:36 +02:00
NuRAD EWI fingering.pdf Added hex files, user guides and fingering charts. 2020-03-24 14:00:44 +01:00
NuRAD key designations.pdf Added hex files, user guides and fingering charts. 2020-03-24 14:00:44 +01:00
NuRAD SAX and EVI fingerings.pdf Fix for SAX fingering and updated fingering chart (NuRAD). Experimental fingerings using rollers for harmonic series (NuEVI). LED indication for extra controller sensor and startup LED check and also fail check for MPR121 sensor boards (NuRAD). 2020-06-04 11:43:46 +02:00
NuRAD user guide 146.doc New version documentation. 2020-04-27 11:21:36 +02:00
NuRAD user guide 146.pdf New version documentation. 2020-04-27 11:21:36 +02:00
nurad-overview.pdf New version documentation. 2020-04-27 11:21:36 +02:00
poly play user guide section.txt Added compile option to include a MPR121 board adress scanning function for troubleshooting (MENU button at startup). Changed the destination setup for bite and lever to be less confusing and more powerful (custom CCs now possible). The VIB CTL item in the VIBRATO menu is now removed, and in SETUP CTL menu you will find BITE CTL, BITE CC, LEVER CTL and LEVER CC. 2020-09-04 11:32:40 +02:00