xevi/uploadable hex files
Johan Berglund c2d429c3f7 * AUTOCAL is available for each ADJUST menu page. With cursor on THR or MAX bar, press UP and DOWN buttons at the same time (and keep off the sensors being calibrated). AUTOCAL will be displayed for two seconds, then updated settings will be shown.
[removed for now - needs work] * Experimental breath controlled harmonic series (BRTH HARM and BR HM SEL settings). Like the lip sensor harmonics function, this shifts the fingered note up the harmonic series. For improved switching speed, try turning down the key deglitch time. (If this function is to be kept, I will probably need to tweak it quite a bit. Tongueing into higher notes and releasing them does not work well currently.)
2020-08-21 07:49:36 +02:00
..
NuEVI-polyplay-beta3.ino.hex For NuRAD: Fix for SAX fingering (LH2+RH2 now plays Bb). Added Gate Hold functionality from NuEVI, using thumb folded in over R2 through R5 in place of the "doorknob" grip on the EVI. For NuRAD and NuEVI: New POLY PLAY functionality with a number of harmonizer settings and additional rotator setups. 2020-07-19 13:52:06 +02:00
NuEVI-pp-brcc-beta4.ino.hex NuEVI and NuRAD: Timing and speed issue solved - SSD1306 display library needed editing to prevent it from lowering I2C bus speed. Added setting to enable/disable the on the fly key switching. NuRAD: Changed touch sensor reading equalisation from offset to multiplier to improve coherence of readings. 2020-07-22 13:24:56 +02:00
NuEVI-v15b1.ino.hex Added automatic sensor calibration performed at factory reset. Changed some default values for settings. 2020-07-23 13:41:13 +02:00
NuEVI-v15b2.ino.hex * Adjustment setting for thumb lever (for optimizing thumb portamento control). By setting THR (level of push force to activate) and MAX (level of push force to achieve maximum set portamento) values close to eachother at the desired point of activation, the new glide limit setting to desired rate will create a switching type set rate controller (similar to Crumar EVI glide key). With THR and MAX setup with separation to taste, a continous control up to level set by glide limit is achieved. 2020-08-19 23:07:38 +02:00
NuEVI-v15b3.ino.hex * AUTOCAL is available for each ADJUST menu page. With cursor on THR or MAX bar, press UP and DOWN buttons at the same time (and keep off the sensors being calibrated). AUTOCAL will be displayed for two seconds, then updated settings will be shown. 2020-08-21 07:49:36 +02:00
NuEVI-v146.ino.hex New version documentation. 2020-04-27 11:21:36 +02:00
NuEVI-v147.ino.hex Fix for SAX fingering and updated fingering chart (NuRAD). Experimental fingerings using rollers for harmonic series (NuEVI). LED indication for extra controller sensor and startup LED check and also fail check for MPR121 sensor boards (NuRAD). 2020-06-04 11:43:46 +02:00
NuRAD-polyplay-beta3.ino.hex For NuRAD: Fix for SAX fingering (LH2+RH2 now plays Bb). Added Gate Hold functionality from NuEVI, using thumb folded in over R2 through R5 in place of the "doorknob" grip on the EVI. For NuRAD and NuEVI: New POLY PLAY functionality with a number of harmonizer settings and additional rotator setups. 2020-07-19 13:52:06 +02:00
NuRAD-pp-brcc-toucheq-beta4.ino.hex NuEVI and NuRAD: Timing and speed issue solved - SSD1306 display library needed editing to prevent it from lowering I2C bus speed. Added setting to enable/disable the on the fly key switching. NuRAD: Changed touch sensor reading equalisation from offset to multiplier to improve coherence of readings. 2020-07-22 13:24:56 +02:00
NuRAD-v15b1.ino.hex Added automatic sensor calibration performed at factory reset. Changed some default values for settings. 2020-07-23 13:41:13 +02:00
NuRAD-v15b2.ino.hex * Adjustment setting for thumb lever (for optimizing thumb portamento control). By setting THR (level of push force to activate) and MAX (level of push force to achieve maximum set portamento) values close to eachother at the desired point of activation, the new glide limit setting to desired rate will create a switching type set rate controller (similar to Crumar EVI glide key). With THR and MAX setup with separation to taste, a continous control up to level set by glide limit is achieved. 2020-08-19 23:07:38 +02:00
NuRAD-v15b3.ino.hex * AUTOCAL is available for each ADJUST menu page. With cursor on THR or MAX bar, press UP and DOWN buttons at the same time (and keep off the sensors being calibrated). AUTOCAL will be displayed for two seconds, then updated settings will be shown. 2020-08-21 07:49:36 +02:00
NuRAD-v146.ino.hex Quick fix... octave setting missing from fingered note calculation for NuRAD 2020-05-17 17:08:22 +02:00
NuRAD-v147.ino.hex Fix for SAX fingering and updated fingering chart (NuRAD). Experimental fingerings using rollers for harmonic series (NuEVI). LED indication for extra controller sensor and startup LED check and also fail check for MPR121 sensor boards (NuRAD). 2020-06-04 11:43:46 +02:00