Commit graph

16 commits

Author SHA1 Message Date
John Stack
c58c3f9e46 Binaries for v1.6.0 2023-02-27 13:25:55 +01:00
Johan Berglund
c8bd07799a * New quarter tone setting for Pinky Key (NuEVI) and Mod Key (NuRAD) – QTN. This makes the Pinky/Mod key a key for playing one quarter tone down using pitchbend (MIDI) or directly affecting the built in note CV output (using CV module or NuEVI CV/Plus). Pitch bend range for MIDI synth needs to be two semitones up/dn (or compensated for in pitch bend divider setting in the controller to make the resulting range two semitones up/dn). On NuRAD, it is recommended to set the 3rd LH Pinky key (EXTRA PKEY setting) to mirror MOD key for playablility.
* Changes to extra controller harmonics settings (experimental). Reverse direction options (ending with an ‘R’) available following the ones going up. This can be used with experimental mouthpieces where increased lip tension creates less touched sensor area.
2021-07-09 14:38:32 +02:00
Johan Berglund
7cb0b1c271 Increased range of CV tuning and scaling. 2021-03-16 16:46:19 +01:00
Johan Berglund
27071c44bd * Added three new settings in EXTRAS MENU – CV TUNE, CV SCALE and CV EC LFO. The first two allow for software tuning of the CV output for 1V/Oct when using NuEVI CV, NuEVI Plus or NuEVI/NuRAD with external CV box or module. Also makes more simple versions of the CV boards possible (no potentiometers for adjustment). The CV EC LFO setting controls a new CV LFO vibrato function for the extra controller (lip sensor). It can be set to OFF (no extra controller LFO vibrato) or values 1 through 8, which represent vibrato freq from 4.5Hz to 8Hz. Default value is 3 (5.5Hz). 2021-02-20 15:35:01 +01:00
Johan Berglund
4cb72f1112 Latest beta (1.5b6) hex files with notes. New overview pdfs. 2021-01-01 13:25:46 +01:00
Johan Berglund
bc545cccc1 * Changed names for ADJUST page titles (to shorten) and added numerical value readouts for THR and MAX settings.
* Corrected start position for rotators and added reset to first position when activated and on roller release (from top five octaves like for the otf key change).
* Adjusted NiMH voltage level
2020-10-10 19:02:25 +02:00
Johan Berglund
b80f9247a2 Added compile option to include a MPR121 board adress scanning function for troubleshooting (MENU button at startup). Changed the destination setup for bite and lever to be less confusing and more powerful (custom CCs now possible). The VIB CTL item in the VIBRATO menu is now removed, and in SETUP CTL menu you will find BITE CTL, BITE CC, LEVER CTL and LEVER CC.
BITE CTL and LEVER CTL can both be set to any of these destinations:
	OFF - no destination active for this controller
	VIB - vibrato
	GLD - glide/portamento (defined by GLIDE MOD and GLIDE LMT settings)
	CC  - custom CC output (defined in GLIDE CC and LEVER CC settings)

Settings in GLIDE CC and LEVER CC are only used when corresponding control is set to CC in its CTL setting as described above.
2020-09-04 11:32:40 +02:00
Johan Berglund
c2d429c3f7 * AUTOCAL is available for each ADJUST menu page. With cursor on THR or MAX bar, press UP and DOWN buttons at the same time (and keep off the sensors being calibrated). AUTOCAL will be displayed for two seconds, then updated settings will be shown.
[removed for now - needs work] * Experimental breath controlled harmonic series (BRTH HARM and BR HM SEL settings). Like the lip sensor harmonics function, this shifts the fingered note up the harmonic series. For improved switching speed, try turning down the key deglitch time. (If this function is to be kept, I will probably need to tweak it quite a bit. Tongueing into higher notes and releasing them does not work well currently.)
2020-08-21 07:49:36 +02:00
Johan Berglund
ee438c200d * Adjustment setting for thumb lever (for optimizing thumb portamento control). By setting THR (level of push force to activate) and MAX (level of push force to achieve maximum set portamento) values close to eachother at the desired point of activation, the new glide limit setting to desired rate will create a switching type set rate controller (similar to Crumar EVI glide key). With THR and MAX setup with separation to taste, a continous control up to level set by glide limit is achieved.
* Glide setting SWO, SWitching Only, sending only Glide on/off (CC#65) for use with synths where glide rate CC#5 is used in non standard ways, for example some DSI/Sequential synths like the Prophet REV2 or Prophet 12 where glide rates are set individually for each oscillator.

* Glide limit setting for portamento. Doubles as setting for portamento level sent using pinky key/mod key in GLD mode. (Can be changed both in menu and in GLD mode.)

* Setting of level for LVL, LVP and GLD now reqires touching both pinky/mod and third trill/RHp3 for setting mode activation, this to avoid accidental change of setting when pinky/mod key is touched.

* Rate of setting movement up and down for LVL, LVP and GLD has been adjusted. Became very much too fast after the timing issues were solved in 1.5b1

* A short delay before note offs in legato transitions is added to make playback of recorded midi behave correctly (keeping note on and note off from being registered on the same timestamp).
2020-08-19 23:07:38 +02:00
Johan Berglund
51f5ab54f6 Added automatic sensor calibration performed at factory reset. Changed some default values for settings. 2020-07-23 13:41:13 +02:00
Johan Berglund
b9a8742fc1 NuEVI and NuRAD: Timing and speed issue solved - SSD1306 display library needed editing to prevent it from lowering I2C bus speed. Added setting to enable/disable the on the fly key switching. NuRAD: Changed touch sensor reading equalisation from offset to multiplier to improve coherence of readings. 2020-07-22 13:24:56 +02:00
Johan Berglund
cc188f2196 For NuRAD: Fix for SAX fingering (LH2+RH2 now plays Bb). Added Gate Hold functionality from NuEVI, using thumb folded in over R2 through R5 in place of the "doorknob" grip on the EVI. For NuRAD and NuEVI: New POLY PLAY functionality with a number of harmonizer settings and additional rotator setups. 2020-07-19 13:52:06 +02:00
Johan Berglund
c7c1825b62 Fix for SAX fingering and updated fingering chart (NuRAD). Experimental fingerings using rollers for harmonic series (NuEVI). LED indication for extra controller sensor and startup LED check and also fail check for MPR121 sensor boards (NuRAD). 2020-06-04 11:43:46 +02:00
Johan Berglund
e68a66db84 Quick fix... octave setting missing from fingered note calculation for NuRAD 2020-05-17 17:08:22 +02:00
Johan Berglund
5791cbbe39 New version documentation. 2020-04-27 11:21:36 +02:00
Johan Berglund
85028a3627 Added hex files, user guides and fingering charts. 2020-03-24 14:00:44 +01:00