xevi/NuEVI
2021-03-16 16:46:19 +01:00
..
adjustmenu.cpp Adjusted default breath cal offset value. Added inverted octave rollers option for NuEVI (EVR in fingering menu). Support for CME WIDI chip connected to Teensy underside pads. Alternate Serial2 TX pad 31 for separate MIDI output, jumper sensing between pads 27 and 28 and power control for WIDI using pad 33. The old "slow midi" function (touching pinky key when pressing enter to toggle on/off) now repurpused for WIDI power control (only available when pads 27 and 28 are bridged). 2021-01-01 11:57:26 +01:00
config.h * Added three new settings in EXTRAS MENU – CV TUNE, CV SCALE and CV EC LFO. The first two allow for software tuning of the CV output for 1V/Oct when using NuEVI CV, NuEVI Plus or NuEVI/NuRAD with external CV box or module. Also makes more simple versions of the CV boards possible (no potentiometers for adjustment). The CV EC LFO setting controls a new CV LFO vibrato function for the extra controller (lip sensor). It can be set to OFF (no extra controller LFO vibrato) or values 1 through 8, which represent vibrato freq from 4.5Hz to 8Hz. Default value is 3 (5.5Hz). 2021-02-20 15:35:01 +01:00
FilterOnePole.cpp Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
FilterOnePole.h Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
globals.h * Added three new settings in EXTRAS MENU – CV TUNE, CV SCALE and CV EC LFO. The first two allow for software tuning of the CV output for 1V/Oct when using NuEVI CV, NuEVI Plus or NuEVI/NuRAD with external CV box or module. Also makes more simple versions of the CV boards possible (no potentiometers for adjustment). The CV EC LFO setting controls a new CV LFO vibrato function for the extra controller (lip sensor). It can be set to OFF (no extra controller LFO vibrato) or values 1 through 8, which represent vibrato freq from 4.5Hz to 8Hz. Default value is 3 (5.5Hz). 2021-02-20 15:35:01 +01:00
hardware.h Adjusted default breath cal offset value. Added inverted octave rollers option for NuEVI (EVR in fingering menu). Support for CME WIDI chip connected to Teensy underside pads. Alternate Serial2 TX pad 31 for separate MIDI output, jumper sensing between pads 27 and 28 and power control for WIDI using pad 33. The old "slow midi" function (touching pinky key when pressing enter to toggle on/off) now repurpused for WIDI power control (only available when pads 27 and 28 are bridged). 2021-01-01 11:57:26 +01:00
led.cpp Fix for SAX fingering and updated fingering chart (NuRAD). Experimental fingerings using rollers for harmonic series (NuEVI). LED indication for extra controller sensor and startup LED check and also fail check for MPR121 sensor boards (NuRAD). 2020-06-04 11:43:46 +02:00
led.h Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
menu.cpp * Added three new settings in EXTRAS MENU – CV TUNE, CV SCALE and CV EC LFO. The first two allow for software tuning of the CV output for 1V/Oct when using NuEVI CV, NuEVI Plus or NuEVI/NuRAD with external CV box or module. Also makes more simple versions of the CV boards possible (no potentiometers for adjustment). The CV EC LFO setting controls a new CV LFO vibrato function for the extra controller (lip sensor). It can be set to OFF (no extra controller LFO vibrato) or values 1 through 8, which represent vibrato freq from 4.5Hz to 8Hz. Default value is 3 (5.5Hz). 2021-02-20 15:35:01 +01:00
menu.h Added compile option to include a MPR121 board adress scanning function for troubleshooting (MENU button at startup). Changed the destination setup for bite and lever to be less confusing and more powerful (custom CCs now possible). The VIB CTL item in the VIBRATO menu is now removed, and in SETUP CTL menu you will find BITE CTL, BITE CC, LEVER CTL and LEVER CC. 2020-09-04 11:32:40 +02:00
midi.cpp Adjusted default breath cal offset value. Added inverted octave rollers option for NuEVI (EVR in fingering menu). Support for CME WIDI chip connected to Teensy underside pads. Alternate Serial2 TX pad 31 for separate MIDI output, jumper sensing between pads 27 and 28 and power control for WIDI using pad 33. The old "slow midi" function (touching pinky key when pressing enter to toggle on/off) now repurpused for WIDI power control (only available when pads 27 and 28 are bridged). 2021-01-01 11:57:26 +01:00
midi.h Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
name.c Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
NuEVI.ino Increased range of CV tuning and scaling. 2021-03-16 16:46:19 +01:00
numenu.cpp Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
numenu.h Added battery type setting and detailed battery info in ABOUT menu (support for NiMH and LiPo batteries). Added lip sensor activated harmonic series, with settings for range and series type. Added NuRAD overview drawing. Changes to CC lables (from 1 & 2 to A & B). 2020-04-27 11:19:08 +02:00
settings.cpp * Added three new settings in EXTRAS MENU – CV TUNE, CV SCALE and CV EC LFO. The first two allow for software tuning of the CV output for 1V/Oct when using NuEVI CV, NuEVI Plus or NuEVI/NuRAD with external CV box or module. Also makes more simple versions of the CV boards possible (no potentiometers for adjustment). The CV EC LFO setting controls a new CV LFO vibrato function for the extra controller (lip sensor). It can be set to OFF (no extra controller LFO vibrato) or values 1 through 8, which represent vibrato freq from 4.5Hz to 8Hz. Default value is 3 (5.5Hz). 2021-02-20 15:35:01 +01:00
settings.h * Added three new settings in EXTRAS MENU – CV TUNE, CV SCALE and CV EC LFO. The first two allow for software tuning of the CV output for 1V/Oct when using NuEVI CV, NuEVI Plus or NuEVI/NuRAD with external CV box or module. Also makes more simple versions of the CV boards possible (no potentiometers for adjustment). The CV EC LFO setting controls a new CV LFO vibrato function for the extra controller (lip sensor). It can be set to OFF (no extra controller LFO vibrato) or values 1 through 8, which represent vibrato freq from 4.5Hz to 8Hz. Default value is 3 (5.5Hz). 2021-02-20 15:35:01 +01:00